Implementation of xSPECT, xSPECT bone and Broadquant from literature, clinical survey and innovative phantom study with task-based image quality assessment.

Fiche publication


Date publication

août 2023

Journal

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

Auteurs

Membres identifiés du Cancéropôle Est :
Pr PAPATHANASSIOU Dimitri


Tous les auteurs :
Hoog C, Verrecchia-Ramos E, Dejust S, Lalire P, Sezin G, Moubtakir A, El Farsaoui K, Caquot PA, Guendouzen S, Morland D, Papathanassiou D

Résumé

From patient and phantom studies, we aimed to highlight an original implementation process and share a two-years experience clinical feedback on xSPECT (xS), xSPECT Bone (xB) and Broadquant quantification (Siemens) for Tc-bone and Lu-NET (neuroendocrine tumors) imaging.

Mots clés

Broadquant, Detectability d', ImQuest, Lesion detectability, NPS, Nuclear Medicine, Quantification, SPECT/CT, TTF, Task-based image quality assessment, Theranostics, xSPECT

Référence

Phys Med. 2023 08;112:102611