Simultaneous, Multi-Channel, Near-Infrared Fluorescence Visualization of Mesenteric Lymph Nodes Using Indocyanine Green and Methylene Blue: A Demonstration in a Porcine Model.

Fiche publication


Date publication

avril 2023

Journal

Diagnostics (Basel, Switzerland)

Auteurs

Membres identifiés du Cancéropôle Est :
Pr MARESCAUX Jacques


Tous les auteurs :
Okamoto N, Al-Difaie Z, Scheepers MHMC, Heuvelings DJI, Rodríguez-Luna MR, Marescaux J, Diana M, Stassen LPS, Bouvy ND, Al-Taher M

Résumé

Near-infrared fluorescence (NIRF) image-guided surgery is a useful tool that can help reduce perioperative complications and improve tissue recognition. Indocyanine green (ICG) dye is the most frequently used in clinical studies. ICG NIRF imaging has been used for lymph node identification. However, there are still many challenges in lymph node identification by ICG. There is increasing evidence that methylene blue (MB), another clinically applicable fluorescent dye, can also be useful in the intraoperative fluorescence-guided identification of structures and tissues. We hypothesized that MB NIRF imaging could be used for lymph node identification. The aim of this study was to evaluate the feasibility of intraoperative lymph node fluorescence detection using intravenously (IV) administered MB and compare it to ICG via a camera that has two dedicated near-infrared (NIR) channels. Three pigs were used in this study. ICG (0.2 mg/kg) was administered via a peripheral venous catheter followed by immediate administration of MB (0.25 mg/kg). NIRF images were acquired as video recordings at different time points (every 10 min) over an hour using the QUEST SPECTRUM 3 system (Quest Medical Imaging, Middenmeer, The Netherlands), which has two dedicated NIR channels for simultaneous intraoperative fluorescence guidance. The 800 nm channel was used to capture ICG fluorescence and the 700 nm channel was used for MB. The target (lymph nodes and small bowel) and the background (vessels-free field of the mesentery) were highlighted as the regions of interest (ROIs), and corresponding fluorescence intensities (FI) from these ROIs were measured. The target-to-background ratio (TBR) was then computed as the mean FI of the target minus the mean FI of the background divided by the mean FI of the background. In all included animals, a clear identification of lymph nodes was achieved at all time points. The mean TBR of ICG in lymph nodes and small bowel was 4.57 ± 1.00 and 4.37 ± 1.70, respectively for the overall experimental time. Regarding MB, the mean TBR in lymph nodes and small bowel was 4.60 ± 0.92 and 3.27 ± 0.62, respectively. The Mann-Whitney U test of the lymph node TBR/small bowel TBR showed that the TBR ratio of MB was statistically significantly higher than ICG. The fluorescence optical imaging technology used allows for double-wavelength assessment. This feasibility study proves that lymph nodes can be discriminated using two different fluorophores (MB and ICG) with different wavelengths. The results suggest that MB has a promising potential to be used to detect lymphatic tissue during image-guided surgery. Further preclinical trials are needed before clinical translation.

Mots clés

colorectal surgery, image-guided surgery, indocyanine green, lymph node, methylene blue, multi-channel, near-infrared fluorescence image, optical imaging, simultaneous

Référence

Diagnostics (Basel). 2023 04 18;13(8):