Gastroscopy-associated transmission of extended-spectrum beta-lactamase-producing Pseudomonas aeruginosa.

Fiche publication


Date publication

avril 2013

Auteurs

Membres identifiés du Cancéropôle Est :
Pr CADIOT Guillaume, Pr THIEFIN Gérard


Tous les auteurs :
Bajolet O, Ciocan D, Vallet C, de Champs C, Vernet-Garnier V, Guillard T, Brasme L, Thiefin G, Cadiot G, Bureau-Chalot F

Résumé

An unusual multi-drug-resistant Pseudomonas aeruginosa (MDR-PA) was isolated in four patients whilst hospitalized in a French teaching hospital between May and August 2011. All four patients had undergone an oesophago-gastro-duodenoscopy with the same gastroscope over a five-month period. This endoscope was associated with a culture positive for the MDR-PA. Observations of endoscope reprocessing identified deviations from the agreed processes: insufficient initial cleaning, shortening of the immersion time and brushing time, insufficient channel flushing, and inadequate drying prior to storage. Since withdrawing the gastroscope and institution of strict adherence to the agreed processes, no other MDR-PA cases have been isolated.